Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Packaging | Series | ProductStatus | OutputIsolation | InternalSwitch(s) | Voltage-Breakdown | Topology | Voltage-StartUp | Voltage-Supply(Vcc/Vdd) | DutyCycle | Frequency-Switching | Power(Watts) | FaultProtection | ControlFeatures | OperatingTemperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
LNK6663VIC OFFLINE SWITCH FLYBACK 12EDIP |
2,189 | 0.72 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch™-HP | Active | Isolated | Yes | 650V | Flyback | - | - | 64% | 120kHz ~ 136kHz | 25 W | Current Limiting, Over Load, Over Temperature, Over Voltage, Short Circuit | - | -40°C ~ 150°C (TJ) |
![]() |
LNK564PGIC OFFLINE SWITCH FLYBACK 8DIP |
3,212 | 0.74 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch®-LP | Active | Isolated | Yes | 700V | Flyback | - | - | 70% | 100kHz | 3 W | Current Limiting, Open Loop, Over Temperature, Short Circuit | - | -40°C ~ 150°C (TJ) |
![]() |
LNK6663EIC OFFLINE SWITCH FLYBACK 7ESIP |
3,999 | 0.78 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch™-HP | Active | Isolated | Yes | 650V | Flyback | - | - | 64% | 120kHz ~ 136kHz | 35 W | Current Limiting, Over Load, Over Temperature, Over Voltage, Short Circuit | - | -40°C ~ 150°C (TJ) |
![]() |
LNK6764VIC OFFLINE SWITCH FLYBACK 12EDIP |
3,564 | 0.83 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch™-HP | Active | Isolated | Yes | 650V | Flyback | - | - | 64% | 120kHz ~ 136kHz | 28 W | Current Limiting, Over Load, Over Temperature, Over Voltage, Short Circuit | - | -40°C ~ 150°C (TJ) |
|
LNK3694PIC OFFLINE SWITCH FLYBACK 8DIP |
3,481 | 0.83 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch™-XT2 | Active | Isolated | Yes | 900V | Flyback | - | - | 65% | 66kHz | 6 W | Current Limiting, Over Temperature, Over Voltage | - | -40°C ~ 150°C (TJ) |
![]() |
LNK364PGIC OFFLINE SWITCH FLYBACK 8DIP |
3,989 | 0.86 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch®-XT | Active | Isolated | Yes | 700V | Flyback | - | - | 60% | 132kHz | 9 W | Current Limiting, Open Loop, Over Temperature, Short Circuit | - | -40°C ~ 150°C (TJ) |
![]() |
LNK6665VIC OFFLINE SWITCH FLYBACK 12EDIP |
3,532 | 0.87 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch™-HP | Active | Isolated | Yes | 650V | Flyback | - | - | 64% | 120kHz ~ 136kHz | 30 W | Current Limiting, Over Load, Over Temperature, Over Voltage, Short Circuit | - | -40°C ~ 150°C (TJ) |
![]() |
LNK6773VIC OFFLINE SWITCH FLYBACK 12EDIP |
3,692 | 0.89 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch™-HP | Active | Isolated | Yes | 725V | Flyback | - | - | 64% | 120kHz ~ 136kHz | 25 W | Current Limiting, Over Load, Over Temperature, Over Voltage, Short Circuit | - | -40°C ~ 150°C (TJ) |
![]() |
LNK6665EIC OFFLINE SWITCH FLYBACK 7ESIP |
3,865 | 0.91 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch™-HP | Active | Isolated | Yes | 650V | Flyback | - | - | 64% | 120kHz ~ 136kHz | 59 W | Current Limiting, Over Load, Over Temperature, Over Voltage, Short Circuit | - | -40°C ~ 150°C (TJ) |
![]() |
LNK6765EIC OFFLINE SWITCH FLYBACK 7ESIP |
2,250 | 0.95 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch™-HP | Active | Isolated | Yes | 650V | Flyback | - | - | 64% | 120kHz ~ 136kHz | 59 W | Current Limiting, Over Load, Over Temperature, Over Voltage, Short Circuit | - | -40°C ~ 150°C (TJ) |
![]() |
LNK6775VIC OFFLINE SWITCH FLYBACK 12EDIP |
3,652 | 1.04 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch™-HP | Active | Isolated | Yes | 725V | Flyback | - | - | 64% | 120kHz ~ 136kHz | 30 W | Current Limiting, Over Load, Over Temperature, Over Voltage, Short Circuit | - | -40°C ~ 150°C (TJ) |
|
LNK604PGIC OFFLINE SWITCH FLYBACK 8DIP |
3,512 | 1.06 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch®-II | Active | Isolated | Yes | 700V | Flyback | - | - | 55% | Up to 85kHz | 4.1 W | Current Limiting, Open Loop, Over Temperature, Short Circuit | - | -40°C ~ 150°C (TJ) |
![]() |
LNK6666EIC OFFLINE SWITCH FLYBACK 7ESIP |
2,604 | 1.06 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch™-HP | Active | Isolated | Yes | 650V | Flyback | - | - | 64% | 120kHz ~ 136kHz | 88 W | Current Limiting, Over Load, Over Temperature, Over Voltage, Short Circuit | - | -40°C ~ 150°C (TJ) |
![]() |
INN2125K-TLIC OFFLINE SW MULT TOP 16ESOP |
2,482 | 1.48 |
RFQ |
![]() Datasheet |
Tape & Reel (TR),Cut Tape (CT) | InnoSwitch™-CE | Active | Isolated | Yes | 650V | Flyback, Secondary Side SR | - | - | 60% | 100kHz | 20 W | Over Temperature, Over Voltage | - | -40°C ~ 105°C (TA) |
![]() |
LNK6766EIC OFFLINE SWITCH FLYBACK 7ESIP |
3,017 | 1.10 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch™-HP | Active | Isolated | Yes | 650V | Flyback | - | - | 64% | 120kHz ~ 136kHz | 88 W | Current Limiting, Over Load, Over Temperature, Over Voltage, Short Circuit | - | -40°C ~ 150°C (TJ) |
![]() |
LNK6775EIC OFFLINE SWITCH FLYBACK 7ESIP |
3,295 | 1.12 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch™-HP | Active | Isolated | Yes | 725V | Flyback | - | - | 64% | 120kHz ~ 136kHz | 59 W | Current Limiting, Over Load, Over Temperature, Over Voltage, Short Circuit | - | -40°C ~ 150°C (TJ) |
|
LNK606PGIC OFFLINE SWITCH FLYBACK 8DIP |
3,236 | 1.14 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch®-II | Active | Isolated | Yes | 700V | Flyback | - | - | 55% | Up to 85kHz | 6.1 W | Current Limiting, Open Loop, Over Temperature, Short Circuit | - | -40°C ~ 150°C (TJ) |
![]() |
INN3275C-H201-TLIC OFFLINE SW MULT TOP 24INSOP |
3,906 | 2.13 |
RFQ |
![]() Datasheet |
Tape & Reel (TR),Cut Tape (CT) | PowiGaN™, InnoSwitch™3-CP | Active | Isolated | Yes | 750V | Flyback, Secondary Side SR | - | - | - | 100kHz | 22 W | Current Limiting, Over Temperature, Over Voltage | - | -40°C ~ 150°C (TJ) |
![]() |
INN3275C-H202-TLIC OFFLINE SW MULT TOP 24INSOP |
3,821 | 2.13 |
RFQ |
![]() Datasheet |
Tape & Reel (TR),Cut Tape (CT) | PowiGaN™, InnoSwitch™3-CP | Active | Isolated | Yes | 750V | Flyback, Secondary Side SR | - | - | - | 100kHz | 22 W | Current Limiting, Over Temperature, Over Voltage | - | -40°C ~ 150°C (TJ) |
![]() |
LNK6667EIC OFFLINE SWITCH FLYBACK 7ESIP |
3,485 | 1.21 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch™-HP | Active | Isolated | Yes | 650V | Flyback | - | - | 64% | 120kHz ~ 136kHz | 117 W | Current Limiting, Over Load, Over Temperature, Over Voltage, Short Circuit | - | -40°C ~ 150°C (TJ) |