Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Packaging | Series | ProductStatus | MountingType | CoilVoltage | ContactForm | ContactRating(Current) | SwitchingVoltage | Features | TerminationStyle | MustOperateVoltage | MustReleaseVoltage | OperateTime | ReleaseTime | OperatingTemperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
7S.14.9.012.4310SFTY RLY GUIDE 3NO+1NC 6A 12VDC |
3,536 | 0.00 |
RFQ |
Bulk | 7S | Active | DIN Rail | 12VDC | 4PST-3NO/1NC (3 Form A, 1 Form B) | 6 A | 250VAC - Nom | Lighted Indicator | Spring Terminal | 9.6 VDC | 1.2 VDC | 12 ms | 10 ms | -40°C ~ 70°C | |
![]() |
7S.63.9.048.0211SFTY RLY GUIDE 2NO+1NC 6A 48VDC |
3,304 | 0.00 |
RFQ |
Bulk | 7S | Active | DIN Rail | 48VDC | 3PST-2NO/1NC (2 Form A, 1 Form B) | 6 A | 250VAC - Nom | Lighted Indicator | Screw Terminal | 40.8 VDC | 4.8 VDC | 10 ms | 7 ms | -40°C ~ 70°C | |
![]() |
7S.36.8.230.5420SFTY RLY GUIDE 4NO+2NC 6A 230VAC |
3,914 | 0.00 |
RFQ |
Bulk | 7S | Active | DIN Rail | 230VAC | 6PST-4NO/2NC (4 Form A, 2 Form B) | 6 A | 250VAC - Nom | Lighted Indicator | Screw Terminal | 195 VAC | 23 VAC | 12 ms | 10 ms | -40°C ~ 70°C | |
![]() |
7S.63.9.110.0211SFTY RLY GUIDE 2NO+1NC 6A 110VDC |
3,659 | 0.00 |
RFQ |
Bulk | 7S | Active | DIN Rail | 110VDC | 3PST-2NO/1NC (2 Form A, 1 Form B) | 6 A | 250VAC - Nom | Lighted Indicator | Screw Terminal | 93.5 VDC | 11 VDC | 10 ms | 7 ms | -40°C ~ 70°C | |
![]() |
7S.43.9.012.0211SFTY RLY GUIDE 2NO+1NC 6A 12VDC |
2,550 | 0.00 |
RFQ |
Bulk | 7S | Active | DIN Rail | 12VDC | 3PST-2NO/1NC (2 Form A, 1 Form B) | 6 A | 250VAC - Nom | Lighted Indicator | Spring Terminal | 10.2 VDC | 1.2 VDC | 10 ms | 7 ms | -40°C ~ 70°C | |
![]() |
7S.14.8.230.4310SFTY RLY GUIDE 3NO+1NC 6A 230VAC |
3,774 | 0.00 |
RFQ |
Bulk | 7S | Active | DIN Rail | 230VAC | 4PST-3NO/1NC (3 Form A, 1 Form B) | 6 A | 250VAC - Nom | Lighted Indicator | Spring Terminal | 195 VAC | 23 VAC | 12 ms | 10 ms | -40°C ~ 70°C | |
![]() |
7S.34.8.230.4310SFTY RLY GUIDE 3NO+1NC 6A 230VAC |
3,221 | 0.00 |
RFQ |
Bulk | 7S | Active | DIN Rail | 230VAC | 4PST-3NO/1NC (3 Form A, 1 Form B) | 6 A | 250VAC - Nom | Lighted Indicator | Screw Terminal | 195 VAC | 23 VAC | 12 ms | 10 ms | -40°C ~ 70°C | |
![]() |
7S.43.9.048.0211SFTY RLY GUIDE 2NO+1NC 6A 48VDC |
2,783 | 0.00 |
RFQ |
Bulk | 7S | Active | DIN Rail | 48VDC | 3PST-2NO/1NC (2 Form A, 1 Form B) | 6 A | 250VAC - Nom | Lighted Indicator | Spring Terminal | 40.8 VDC | 4.8 VDC | 10 ms | 7 ms | -40°C ~ 70°C | |
![]() |
7S.63.9.012.0211SFTY RLY GUIDE 2NO+1NC 6A 12VDC |
2,253 | 0.00 |
RFQ |
Bulk | 7S | Active | DIN Rail | 12VDC | 3PST-2NO/1NC (2 Form A, 1 Form B) | 6 A | 250VAC - Nom | Lighted Indicator | Screw Terminal | 10.2 VDC | 1.2 VDC | 10 ms | 7 ms | -40°C ~ 70°C | |
![]() |
7S.34.9.012.4220SFTY RLY GUIDE 2NO+2NC 6A 12VDC |
2,915 | 0.00 |
RFQ |
Bulk | 7S | Active | DIN Rail | 12VDC | 4PST-2NO/2NC (2 Form A, 2 Form B) | 6 A | 250VAC - Nom | Lighted Indicator | Screw Terminal | 9.6 VDC | 1.2 VDC | 12 ms | 10 ms | -40°C ~ 70°C | |
![]() |
7S.34.9.012.4310SFTY RLY GUIDE 3NO+1NC 6A 12VDC |
3,816 | 0.00 |
RFQ |
Bulk | 7S | Active | DIN Rail | 12VDC | 4PST-3NO/1NC (3 Form A, 1 Form B) | 6 A | 250VAC - Nom | Lighted Indicator | Screw Terminal | 9.6 VDC | 1.2 VDC | 12 ms | 10 ms | -40°C ~ 70°C | |
![]() |
7S.14.9.012.4220SFTY RLY GUIDE 2NO+2NC 6A 12VDC |
2,336 | 0.00 |
RFQ |
Bulk | 7S | Active | DIN Rail | 12VDC | 4PST-2NO/2NC (2 Form A, 2 Form B) | 6 A | 250VAC - Nom | Lighted Indicator | Spring Terminal | 9.6 VDC | 1.2 VDC | 12 ms | 10 ms | -40°C ~ 70°C | |
![]() |
7S.34.8.230.4220SFTY RLY GUIDE 2NO+2NC 6A 230VAC |
2,233 | 0.00 |
RFQ |
Bulk | 7S | Active | DIN Rail | 230VAC | 4PST-2NO/2NC (2 Form A, 2 Form B) | 6 A | 250VAC - Nom | Lighted Indicator | Screw Terminal | 195 VAC | 23 VAC | 12 ms | 10 ms | -40°C ~ 70°C | |
![]() |
7S.63.9.024.0211SFTY RLY GUIDE 2NO+1NC 6A 24VDC |
2,157 | 0.00 |
RFQ |
Bulk | 7S | Active | DIN Rail | 24VDC | 3PST-2NO/1NC (2 Form A, 1 Form B) | 6 A | 250VAC - Nom | Lighted Indicator | Screw Terminal | 20.4 VDC | 2.4 VDC | 10 ms | 7 ms | -40°C ~ 70°C | |
![]() |
7S.36.8.120.5420SFTY RLY GUIDE 4NO+2NC 6A 120VAC |
2,085 | 0.00 |
RFQ |
Bulk | 7S | Active | DIN Rail | 120VAC | 6PST-4NO/2NC (4 Form A, 2 Form B) | 6 A | 250VAC - Nom | Lighted Indicator | Screw Terminal | 93 VAC | 12 VAC | 12 ms | 10 ms | -40°C ~ 70°C | |
![]() |
7S.16.9.110.5420SFTY RLY GUIDE 4NO+2NC 6A 110VDC |
3,953 | 0.00 |
RFQ |
Bulk | 7S | Active | DIN Rail | 110VDC | 6PST-4NO/2NC (4 Form A, 2 Form B) | 6 A | 250VAC - Nom | Lighted Indicator | Spring Terminal | 77 VDC | 11 VDC | 12 ms | 10 ms | -40°C ~ 70°C | |
![]() |
7S.23.9.012.0210SFTY RLY GUIDE 2NO+1NC 10A 12VDC |
3,512 | 0.00 |
RFQ |
Bulk | 7S | Active | DIN Rail | 12VDC | 3PST-2NO/1NC (2 Form A, 1 Form B) | 10 A | 250VAC - Nom | Lighted Indicator | Screw Terminal | 9.6 VDC | 1.2 VDC | 7 ms | 11 ms | -40°C ~ 70°C |