Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Packaging | Series | ProductStatus | Type | Function | ActuatorType | OperatingPressure | OrificeDiameter | FluidType | ConnectionMethod | ForUseWith/RelatedProducts | MountingType |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
BM-91-530-HNR-1615/3-WAY, ELECTRICALLY OPERATED P |
2,674 | 121.73 |
RFQ |
![]() Datasheet |
Box | BM | Active | Solenoid Valve | 5/3 | - | 44 ~ 116 PSI (3 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount |
![]() |
BM-91-534-HNR-1315/3-WAY, ELECTRICALLY OPERATED P |
2,762 | 121.73 |
RFQ |
![]() Datasheet |
Box | BM | Active | Solenoid Valve | 5/3 | - | 44 ~ 116 PSI (3 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount |
![]() |
BM-91-533-HNR-1315/3-WAY, ELECTRICALLY OPERATED P |
3,788 | 121.73 |
RFQ |
![]() Datasheet |
Box | BM | Active | Solenoid Valve | 5/3 | - | 44 ~ 116 PSI (3 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount |
![]() |
BM-91-533-HNR-1615/3-WAY, ELECTRICALLY OPERATED P |
2,653 | 121.73 |
RFQ |
![]() Datasheet |
Box | BM | Active | Solenoid Valve | 5/3 | - | 44 ~ 116 PSI (3 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount |
![]() |
BM-91-530-HNR-1315/3-WAY, ELECTRICALLY OPERATED P |
3,903 | 121.73 |
RFQ |
![]() Datasheet |
Box | BM | Active | Solenoid Valve | 5/3 | - | 44 ~ 116 PSI (3 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount |
![]() |
BM-91-530-HNR-1325/3-WAY, ELECTRICALLY OPERATED P |
3,554 | 121.73 |
RFQ |
![]() Datasheet |
Box | BM | Active | Solenoid Valve | 5/3 | - | 44 ~ 116 PSI (3 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount |
![]() |
BM-91-533-HNR-1625/3-WAY, ELECTRICALLY OPERATED P |
2,062 | 121.73 |
RFQ |
![]() Datasheet |
Box | BM | Active | Solenoid Valve | 5/3 | - | 44 ~ 116 PSI (3 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount |
![]() |
BM-91-530-HNR-1625/3-WAY, ELECTRICALLY OPERATED P |
3,646 | 121.73 |
RFQ |
![]() Datasheet |
Box | BM | Active | Solenoid Valve | 5/3 | - | 44 ~ 116 PSI (3 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount |
![]() |
BM-91-534-HNR-1325/3-WAY, ELECTRICALLY OPERATED P |
2,047 | 121.73 |
RFQ |
![]() Datasheet |
Box | BM | Active | Solenoid Valve | 5/3 | - | 44 ~ 116 PSI (3 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount |
![]() |
BM-91-534-HNR-1615/3-WAY, ELECTRICALLY OPERATED P |
3,294 | 121.73 |
RFQ |
![]() Datasheet |
Box | BM | Active | Solenoid Valve | 5/3 | - | 44 ~ 116 PSI (3 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount |
![]() |
BM-91-534-HNR-1625/3-WAY, ELECTRICALLY OPERATED P |
2,329 | 121.73 |
RFQ |
![]() Datasheet |
Box | BM | Active | Solenoid Valve | 5/3 | - | 44 ~ 116 PSI (3 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount |
![]() |
BM-91-312-HNR-1323/2-WAY NO, ELECTRICALLY OPERATE |
3,764 | 122.55 |
RFQ |
![]() Datasheet |
Box | BM | Active | Solenoid Valve | 3/2 Normally Open | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount |
![]() |
BM-91-312-HNR-1613/2-WAY NO, ELECTRICALLY OPERATE |
3,832 | 122.55 |
RFQ |
![]() Datasheet |
Box | BM | Active | Solenoid Valve | 3/2 Normally Open | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount |
![]() |
BM-91-312-HNR-1313/2-WAY NO, ELECTRICALLY OPERATE |
3,867 | 122.55 |
RFQ |
![]() Datasheet |
Box | BM | Active | Solenoid Valve | 3/2 Normally Open | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount |
![]() |
BM-91-310/2-HNR-1322 X 3/2-WAY NC, ELECTRICALLY OPE |
3,841 | 122.55 |
RFQ |
![]() Datasheet |
Box | BM | Active | Solenoid Valve | 2 x 3/2 Normally Closed | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount |
![]() |
BM-91-312-HNR-1623/2-WAY NO, ELECTRICALLY OPERATE |
3,606 | 122.55 |
RFQ |
![]() Datasheet |
Box | BM | Active | Solenoid Valve | 3/2 Normally Open | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount |
![]() |
BM-91-310/2-HNR-1312 X 3/2-WAY NC, ELECTRICALLY OPE |
2,503 | 122.55 |
RFQ |
![]() Datasheet |
Box | BM | Active | Solenoid Valve | 2 x 3/2 Normally Closed | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount |
![]() |
BM-91-310/2-HNR-1612 X 3/2-WAY NC, ELECTRICALLY OPE |
2,615 | 122.55 |
RFQ |
![]() Datasheet |
Box | BM | Active | Solenoid Valve | 2 x 3/2 Normally Closed | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount |
![]() |
BM-91-310/2-HNR-1622 X 3/2-WAY NC, ELECTRICALLY OPE |
3,537 | 122.55 |
RFQ |
![]() Datasheet |
Box | BM | Active | Solenoid Valve | 2 x 3/2 Normally Closed | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount |
![]() |
BM-91-312/2-HNR-1612 X 3/2-WAY NO, ELECTRICALLY OPE |
2,761 | 122.55 |
RFQ |
![]() Datasheet |
Box | BM | Active | Solenoid Valve | 2 x 3/2 Normally Open | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount |