Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Packaging | Series | ProductStatus | OutputIsolation | InternalSwitch(s) | Voltage-Breakdown | Topology | Voltage-StartUp | Voltage-Supply(Vcc/Vdd) | DutyCycle | Frequency-Switching | Power(Watts) | FaultProtection | ControlFeatures | OperatingTemperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
PKS604YNIC OFFLINE SW FLYBACK TO220-7C |
3,589 | 0.00 |
RFQ |
![]() Datasheet |
Tube | PeakSwitch® | Obsolete | Isolated | Yes | 700V | Flyback | - | - | 65% | 277kHz | 56 W | Current Limiting, Over Load, Over Temperature | EN | -40°C ~ 150°C (TJ) |
![]() |
PKS605YNIC OFFLINE SW FLYBACK TO220-7C |
2,032 | 0.00 |
RFQ |
![]() Datasheet |
Tube | PeakSwitch® | Obsolete | Isolated | Yes | 700V | Flyback | - | - | 65% | 277kHz | 79 W | Current Limiting, Over Load, Over Temperature | EN | -40°C ~ 150°C (TJ) |
![]() |
PKS606YNIC OFFLINE SW FLYBACK TO220-7C |
3,394 | 0.00 |
RFQ |
![]() Datasheet |
Tube | PeakSwitch® | Obsolete | Isolated | Yes | 700V | Flyback | - | - | 65% | 277kHz | 117 W | Current Limiting, Over Load, Over Temperature | EN | -40°C ~ 150°C (TJ) |
![]() |
PKS604FNIC OFFLINE SW FLYBACK TO262-7C |
2,872 | 0.00 |
RFQ |
![]() Datasheet |
Tube | PeakSwitch® | Obsolete | Isolated | Yes | 700V | Flyback | - | - | 65% | 277kHz | 56 W | Current Limiting, Over Load, Over Temperature | EN | -40°C ~ 150°C (TJ) |
![]() |
PKS605FNIC OFFLINE SW FLYBACK TO262-7C |
2,178 | 0.00 |
RFQ |
![]() Datasheet |
Tube | PeakSwitch® | Obsolete | Isolated | Yes | 700V | Flyback | - | - | 65% | 277kHz | 79 W | Current Limiting, Over Load, Over Temperature | EN | -40°C ~ 150°C (TJ) |
![]() |
PKS606FNIC OFFLINE SW FLYBACK TO262-7C |
2,274 | 0.00 |
RFQ |
![]() Datasheet |
Tube | PeakSwitch® | Obsolete | Isolated | Yes | 700V | Flyback | - | - | 65% | 277kHz | 117 W | Current Limiting, Over Load, Over Temperature | EN | -40°C ~ 150°C (TJ) |
![]() |
LNK302DNIC OFFLINE SWITCH MULT TOP 8SO |
2,838 | 0.00 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch®-TN | Discontinued at Mosen | Non-Isolated | Yes | 700V | Buck, Buck-Boost, Flyback | - | - | 69% | 66kHz | - | Current Limiting, Open Loop, Over Temperature, Short Circuit | - | -40°C ~ 150°C (TJ) |
![]() |
LNK304DNIC OFFLINE SWIT OCP 8SOIC |
3,369 | 0.00 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch®-TN | Discontinued at Mosen | Non-Isolated | Yes | 700V | Buck, Buck-Boost, Flyback | - | - | 69% | 66kHz | - | Current Limiting, Open Loop, Over Temperature, Short Circuit | - | -40°C ~ 150°C (TJ) |
![]() |
LNK305DNIC OFFLINE SWITCH MULT TOP 8SO |
2,328 | 0.00 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch®-TN | Discontinued at Mosen | Non-Isolated | Yes | 700V | Buck, Buck-Boost, Flyback | - | - | 69% | 66kHz | - | Current Limiting, Open Loop, Over Temperature, Short Circuit | - | -40°C ~ 150°C (TJ) |
![]() |
LNK306DNIC OFFLINE SWITCH MULT TOP 8SO |
3,536 | 0.00 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch®-TN | Discontinued at Mosen | Non-Isolated | Yes | 700V | Buck, Buck-Boost, Flyback | - | - | 69% | 66kHz | - | Current Limiting, Open Loop, Over Temperature, Short Circuit | - | -40°C ~ 150°C (TJ) |
![]() |
LNK362DNIC OFFLINE SWITCH FLYBACK 8SO |
2,695 | 0.00 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch®-XT | Discontinued at Mosen | Isolated | Yes | 700V | Flyback | - | - | 60% | 132kHz | 2.8 W | Current Limiting, Open Loop, Over Temperature, Short Circuit | - | -40°C ~ 150°C (TJ) |
![]() |
LNK363DNIC OFFLINE SWITCH FLYBACK 8SO |
2,867 | 0.00 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch®-XT | Discontinued at Mosen | Isolated | Yes | 700V | Flyback | - | - | 60% | 132kHz | 7.5 W | Current Limiting, Open Loop, Over Temperature, Short Circuit | - | -40°C ~ 150°C (TJ) |
![]() |
LNK364DNIC OFFLINE SWITCH FLYBACK 8SO |
2,250 | 0.00 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch®-XT | Discontinued at Mosen | Isolated | Yes | 700V | Flyback | - | - | 60% | 132kHz | 9 W | Current Limiting, Open Loop, Over Temperature, Short Circuit | - | -40°C ~ 150°C (TJ) |
![]() |
LNK562DNIC OFFLINE SWITCH FLYBACK 8SO |
2,649 | 0.00 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch®-LP | Discontinued at Mosen | Isolated | Yes | 700V | Flyback | - | - | 70% | 66kHz | 1.9 W | Current Limiting, Open Loop, Over Temperature, Short Circuit | - | -40°C ~ 150°C (TJ) |
![]() |
LNK563DNIC OFFLINE SWITCH FLYBACK 8SO |
2,497 | 0.00 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch®-LP | Discontinued at Mosen | Isolated | Yes | 700V | Flyback | - | - | 70% | 83kHz | 2.5 W | Current Limiting, Open Loop, Over Temperature, Short Circuit | - | -40°C ~ 150°C (TJ) |
![]() |
LNK564DNIC OFFLINE SWITCH FLYBACK 8SO |
2,536 | 0.00 |
RFQ |
![]() Datasheet |
Tube | LinkSwitch®-LP | Discontinued at Mosen | Isolated | Yes | 700V | Flyback | - | - | 70% | 100kHz | 3 W | Current Limiting, Open Loop, Over Temperature, Short Circuit | - | -40°C ~ 150°C (TJ) |
|
PKS607FNIC OFFLINE SW FLYBACK TO262-7C |
3,620 | 0.00 |
RFQ |
![]() Datasheet |
Tube | PeakSwitch® | Obsolete | Isolated | Yes | 700V | Flyback | - | - | 65% | 277kHz | 126 W | Current Limiting, Over Load, Over Temperature | EN | -40°C ~ 150°C (TJ) |
|
PKS607YNIC OFFLINE SW FLYBACK TO220-7C |
3,893 | 0.00 |
RFQ |
![]() Datasheet |
Tube | PeakSwitch® | Obsolete | Isolated | Yes | 700V | Flyback | - | - | 65% | 277kHz | 126 W | Current Limiting, Over Load, Over Temperature | EN | -40°C ~ 150°C (TJ) |
|
TNY375PNIC OFFLINE SWITCH FLYBACK 8DIP |
2,605 | 0.00 |
RFQ |
![]() Datasheet |
Tube | TinySwitch®-PK | Obsolete | Isolated | Yes | 700V | Flyback | - | - | 65% | 132kHz ~ 264kHz | 15 W | Current Limiting, Over Load, Over Temperature, Over Voltage | EN | -40°C ~ 150°C (TJ) |
|
TNY376PNIC OFFLINE SWITCH FLYBACK 8DIP |
3,348 | 0.00 |
RFQ |
![]() Datasheet |
Tube | TinySwitch®-PK | Obsolete | Isolated | Yes | 700V | Flyback | - | - | 65% | 132kHz ~ 264kHz | 19 W | Current Limiting, Over Load, Over Temperature, Over Voltage | EN | -40°C ~ 150°C (TJ) |